background image

 
 

#  tsDMT300RF   RevB 03/21/2011

                                                                                                                                                            3 

 

Component

Voltage

Water Valve

120vac

1.2 KΩ

Drain Pump

120vac

37Ω-42Ω

Heater

120vac

13Ω

Fan Mtr

120vac

1.8kΩ

Disp Wax Mtr

120vac

2.3KΩ

Thermal Actuator

1.45kΩ

Circulation Mtr

120vac

21.5Ω

Resistance (kΩ)

Temp. 

(ºF)

Resistance 

(kΩ)

Temp. 

(ºF)

125.78

41

26.065

104

98.323

50

21.385

113

77.454

59

17.599

122

61.465

68

14.579

131

49.12

77

12.14

140

39.517

86

10.159

149

31.996

95

8.542

158

Thermistor

Components

CN01 CN1 PBA Power                              

1 120vac L1 (Wht)                         
3 120vac N (Blk)

 

CN302                                              

1-6 Power Relay Driver (Blk-Org)     
2-6 Heater Relay Driver (Red-Org)             
4-Trubidity Receiver (Yel)                      
5-Trubidity Transmitter (Brn)                  
7-6   5vdc (Pnk-Org)                                        
8-Rinse Aid Sensor (Gry)                     
9-6 12vdc (Wht-Org) (Pwr On)                       
9-6  6vdc (Wht-Org) (Pwr Off)

 

CN301                             

1-Low Water Sensor       
3-Overflow Sensor          
5-Water Counter             
6-Leakage Sensor           
8-Thermistor                    
9– 12vdc                       
10-Door Check Receiver 

 

CN803 Key Driver      

10-11  5vdc

 

Main PCB 

 

CN201                                                                                                          

1-(CN101-1) Wash Mtr (Red-Wht) 120vac (Ω test to Yel on Disp)                             
2-(CN101-1) Fan Mtr (S/Blu-Wht) 120vac (Ω test to Yel on Disp)                                                                
5-(CN101-1) Disp Wax Mtr (Wht-Wht) 120vac (Ω test to Yel on Disp)                                                       
7-(CN101-1) Inlet Valve (Brn-Wht) 120vac (Ω test to Yel on Disp)                                                              
8-(CN101-1) Drain Pump (Org-Wht) 120vac

 

Summary of Contents for DMT300RFB/XAA

Page 1: ... with a separate rinse additive in the dispenser gives better drying performance For tough baked on soils an Enzyme detergent is better at hydration of the food soils For staining such as tomato coffee and tea a detergent with Chlorine bleach will work on the stains much better than an Enzyme based detergent Now that phosphate content in dishwasher detergent has plummeted to 0 5 percent from as hi...

Page 2: ... tsDMT300RF RevB 03 21 2011 2 ...

Page 3: ... Wht 3 120vac N Blk CN302 1 6 Power Relay Driver Blk Org 2 6 Heater Relay Driver Red Org 4 Trubidity Receiver Yel 5 Trubidity Transmitter Brn 7 6 5vdc Pnk Org 8 Rinse Aid Sensor Gry 9 6 12vdc Wht Org Pwr On 9 6 6vdc Wht Org Pwr Off CN301 1 Low Water Sensor 3 Overflow Sensor 5 Water Counter 6 Leakage Sensor 8 Thermistor 9 12vdc 10 Door Check Receiver CN803 Key Driver 10 11 5vdc Main PCB CN201 1 CN1...

Page 4: ...or stuck close issue clean it with mild soap water The residue can foul the mating latch 3 If the customer uses tablets or some self contained type of soap tab make sure it is fully seated and the door does not sandwich it shut 4 Make sure that in the rack nearest to the dispenser door when the door is shut is not obstructing the opening of the dispenser with some protruding utensil Testing The De...

Page 5: ...ly does not oc cur 5 minutes after the water supply starts Alien particles within water supply valve Water supply valve terminal not con nected Possible defect Main PB Water supply valve Flow Meter High temp Water error When 80 or above is detected during water supply Water supply temperature of 80 or above Possible defect Thermistor Main PBA Drain error When OFF status of Low Level S W is not det...

Page 6: ... Overflow Sensor Over level water error Water is supplied until Over Level Water Error Heavy Quick LED is blinked If Over Level Water Error occurs overflow sensor is OK No 6 Heavy Delicate Quick LED Drain Pump Low Level Sensor Drain Error Drain pump will work until low level is detected If Low level is not detected after 60 seconds Drain Error Delicate LED will blink No 7 Normal Quick LED Inlet Va...

Reviews: