INSTALLATION
TECHNICAL MANUAL
PART 2 JUNE 2002
2.2
The system maximum capacity is as follows:
SYSTEM MAXIMUM CAPACITY
STATIONS
16 (12 Keysets, 4 SLTs)
ANALOG TRUNK CIRCUITS
3/6
MUSIC CHANNEL
1 (Internal or External)
EXTERNAL PAGE
1
GENERAL PURPOSE DRY CONTACT 1
1
SERIAL I/O PORTS
2 (DB 9 Connectors)
AUTO ATTENDANT CHANNELS
4
ANALOG CALLER ID CHANNELS
8 (Non-Blocking)
NOTES:
1. Only one (1) trunk expansion card (3 TRK card or 6 TRK card) can be installed.
2. Connectors are provided for the installation of one SIO option board, and one
AA option board.
3. The Analog Caller-ID presentation facility requires installation of the SIO2 card in
addition to an analog trunk card (a 3 TRK card or 6 TRK card).
2.3 MOUNTING THE KSU
The DS 616 KSU must be wall-mounted in a vertical position. The KSU should be
mounted on a plywood backboard at least 5/8” thick.
If the KSU is to be mounted on a wall with no plywood backboard, it should be
mounted on a section of wall capable of holding the weight of the system and cables
(approximately 11 lbs. fully loaded). Preferably close to a stud in the wall.
Attach the wall-mount bracket to the backboard with the screws supplied and hang the
KSU on the bracket.
2.4 GROUNDING
An equipment grounding conductor that is not smaller in size than the ungrounded
branch-circuit supply conductors is to be installed as part of the circuit that supplies the
product or system. Bare, covered, or insulated grounding conductors are acceptable.