60 _ Troubleshooting
Error Type
Error mode
Checking method
Corrective actions
Detergent
is not
dispensed
None
1. Check whether detergent is inserted into the dispenser.
- Check whether there is detergent in the Dispenser.
2. Check the connections for the Dispenser connector.
- Reconnect the Dispenser connector.
3. Check the resistance of the Dispenser.(Remove the
connector before measuring.)
1RUPDO$SSUR[aNȍ
- Faulty: Replace the Dispenser.
4. Check the operation of the Dispenser Relay
: Check the operating voltage between the Black wire of
the CN201 connector and the Black wire of the CN101
connector.
Normal: 110V ~ 120V (while operating)
- Faulty: Replace the Main PBA assy.
No washing
None
&KHFNWKH¿OWHU
)DXOW\5HSODFH¿OWHU
2. Check Rotors and ducts and vane
- Faulty: Replace Rotors and ducts.
3. Check the operation of the half load.
- See “PE Error”.