Troubleshooting_49
Check type
Check code
Checking method
Corrective actions
No Washing
None
1. Check whether the nozzle injects water normally.
- See “The nozzle does not inject water”.
2. Check the operation of the Heater.
- See “Heater Check”.
Detergent is not
dispensed.
None
1. Check whether detergent is inserted into the dispenser.
- Check whether there is detergent in the Dispenser.
2. Check the connections for the Dispenser connector.
- Reconnect the Dispenser connector.
3. Check the resistance of the Dispenser.
(Remove the connector before measuring.)
�
Normal: Approx. 2.3 kΩ
- Faulty: Replace the Dispenser.
4.Check the operation of the Dispenser Relay.
: Check the operating voltage between the white wire of the CN101 connector
and the white black of the CN202 connector.
�
Normal: 120V (while operating)
-Faulty: Replace the Main PBA assy.
- Check voltage