12 English
Connecting the power
Connecting the power
Connecting the power
CAUTION
You must check voltage after connecting power cord.
Live 1 - Neutral
120 V
Live 2 - Neutral
120 V
Live 1 - Live 2
208 V / 240 V
Installing a 4-wire conduit
• Aluminum building wire may be used but it must be rated for the correct
amperage and voltage to make the connection. Connect the wires as described
below.
• The wire you use, the location and enclosure of splices, etc., must conform to
good wiring practices and local codes.
1.
Loosen the 3 lower terminal screws from the terminal block. Remove the
ground screw and ground plate and retain them.
2. Cut and discard the ground strap. Do not discard any screws.
3.
Insert the ground bare wire tip between the range frame and the ground
plate (removed earlier) and secure it in place with the ground screw (removed
earlier).
4.
Insert the bare wire (white/neutral) tip through the bottom center of the
terminal block opening.
5.
Insert the two side bare wire tips into the lower left and the lower right
terminal block openings.
6.
Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not
over-tighten the screws since it could damage the wires.
7.
Go to
Step 5
on page 13 to continue with the installation.
Neutral
terminal
Live 2
Ground
wire (Green)
Wire tips
Ground strap
Ground plate
Black
Black
White
White
Red
Red
Live 1
CAUTION
You must check voltage after connecting power cord.
Live 1 - Neutral
120 V
Live 2 - Neutral
120 V
Live 1 - Live 2
208 V / 240 V
Install_NE63T8911_AA_DG68-01257A-00_EN.indd 12