8 English
Connecting the power
Connecting the power
Connecting the power
Step 2. Accessing the power cord connection
Loosen and then remove the rear access cover screw with a screwdriver. Remove
the rear access cover by pull right and then out. The terminal block will then be
accessible.
Terminal block
Access cover
Specified rating of power-supply-cord kit and circuit protection
Range rating, watts
Specified rating
of power-supply-
cord kit and
circuit protection,
Amps
Diameter (inches) of range
connection opening
120/240 volts
3-wire
120/208 volts
3-wire
Power cord
Conduit
8750-16500
7801-12500
40 or 50 A
1
3
⁄
8
"
1
1
⁄
8
"
This appliance must be supplied with the proper voltage at the proper frequency
and must be connected to a dedicated, properly grounded branch circuit protected
by a 40 amp or larger circuit breaker.