38
2.10 PLU PROGRAMMING
HASH PLU
’
s operation is the same as HASH department operation.
PLU
is
registered by
sequential index ( 1 ~ 1000 )
or
by PLU code ( 1 ~ 99999999 )
that you program.
(
SYSTEM OPTION ADDRESS 9
,
Page 22
)
Although you don
’
t program PLU code, each PLU has a default code that is same as the PLU
number.
2.10.1 PLU PROGRAMMING
A. PROGRAMMING OPTION
PROGRAMMING OPTION
VALUE
OPTION DIGIT
Resettable counter
, counter will
increase
.
Nonresettable counter
, counter will
increase
.
Resettable counter
, counter will
decrease
.
Nonresettable counter
, counter will
decrease
.
0
1
2
3
N 1
HASH PLU
feature
GALLONAGE PLU
feature
NON-ADD NUMBER
compulsory
a
b
c
YES = 1
YES = 2
YES = 4
NO = 0
NO = 0
NO = 0
N 2 = a + b + c
PLU is
NEGATIVE
.
PLU is
SINGLE ITEM
.
VALIDATION compulsory
a
b
c
YES = 1
YES = 2
YES = 4
NO = 0
NO = 0
NO = 0
N 3 = a + b + c
PLU is
PRESET
.
PLU is O
PEN ( HALO )
.
PLU is
DISABLED
.
0
1
2
N 4
PLU is
not taxable
.
PLU is taxable by
VAT 1
.
PLU is taxable by
VAT 2
.
PLU is taxable by
VAT 3
.
PLU is taxable by
VAT 4
.
PLU is taxable by
VAT 1 & 3
.
0
1
2
3
4
5
N 5
PLU is printed on
KITCHEN PRINTER
a YES = 1
NO = 0
N 6
Summary of Contents for ER-5100
Page 23: ...22 ...
Page 28: ...27 Validation on CASH TEND tendering is compulsory c YES 4 NO 0 ...
Page 30: ...29 NO 0 68 Disable printing FOREIGN AMOUNT during Conversion operation a YES 1 NO 0 a ...
Page 33: ...32 2 8 3 DESCRIPTOR PROGRAMMING SCAN PAID OUT CASH TEND ...
Page 47: ...46 2 19 PARAMETERS PROGRAM SCAN SUBTL CASH TEND ...