4
_ Preparing to install the range
ChECKinG thE instAllAtion sitE
Clearances and dimensions
To install the range, refer to the following figure.
For installation in CANADA, a Free-standing range is not to be installed closer than 12mm
from any adjacent surface.
CAUTION
CAUTION
This range has been designed to comply with the maximum allowable wood
cabinet temperatures of 194°F. Make sure the wall covering, countertops and cabinets around the
range can withstand the heat (up to 194°F) generated by the range. If not, discoloration, delamination
or melting may occur.
A
B
36”
30”
24”
6”
25”
3”
24”
3”
A : Cabinet opening
30” For U.S.A,
30”~31” For CANADA.
B : Acceptable electrical
outlet area
Minimum dimensions
IMPORTANT
To eliminate the risk of burns or fire caused by reaching over heated surface
units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to
be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of
5” beyond the bottom of the cabinets.
* 30”
30”
** 15”
*
30” minimum clearance between the top
of the cooking surface and the bottom of
an unprotected wood or metal cabinet;
or 24” minimum when the bottom of the
wood or metal cabinet is protected by not
less than
1
/
4
” flame retardant millboard
covered with not less than no.28 MSG
sheet steel, 0.015” stainless steel, 0.024”
aluminum or 0.020” copper.
**
15” minimum between the countertop and
the adjacent cabinet bottom.