13
3. Disassembly and Reassembly
3-2 Removing PCB-Sub & L.V.Trans
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range . Replace all panels before operating range . Failure to do so
can result in death or electrical shock .
PRECAUTION
When you work on the electric range, be careful when handling the sheet metal parts . Sharp edges may
be present, and you can cut yourself if you are not careful .
Parts
Explaination Photo
Explaination
PCB-Sub &
L .V .Trans
1.
Turn off the electrical supply
going to the range .
2.
Pull the range away from the
wall so that you can access the
rear panel .
3.
Remove Cover-Back Main Wire
and Cover-Back Guard Wire
(See step 4 on page 12)
4.
There are 2 PCB’s (power
control board) . When you
check PCB, check the proper
PCB in default mode and check
main PCB .
5.
To remove the control power
supply:
a) Disconnect 2 connectors .
b) Remove the two screws .
PCB-Sub
2 Screws