3
4. Troubleshooting
4-1 Failure Display Codes
Safety error
“E-08” or
“E-0A”
* Replace main PCB
* Solder again if pattern is damaged
or parts is wrong contacted.
No
* Check the DLB, Bake and Broil relay.
(Nomal:
Ω)
* Check whether there is any damaged
parts of PCB pattern.
* Measure oven sensor resistance.
(1080Ω at the room temperature)
* Check the connecting condition of
harness related with oven sensor.
* Check connector and harness connected to PCB.
* Check whether harness on connector
(CN04,CN05) of sub PCB is connected normally into the
connector(CN04,CN05) or not.
Disconnect power and main PCB
Ok
Ok
Ok
No
END
*Reconnect after replacing the oven
sensor.
No
Replace or repair the harness.
With replacing main PCB, and make set work.
No
Replace main PCB
END
END
∞
Broil Relay
Broil Relay
Bake Relay
Bake Relay
DLB Relay
DLB Relay
Sub PCB
Main PCB