background image

Technical Support Guide

 

Epica DGX 16/32 and Enova DGX Cable Management

 

1

 

 

 

Technical Support Guide

 

Epica DGX 16/32 and Enova DGX Cable Management

 

Applicability

 

This 

Technical Support Guide 

provides instructions for installing (and removing) cable management bars for 

SC Optical Boards 

on 

Epica DGX 16/32 Distribution Matrices and for 

DXLink Fiber Boards 

on all Enova DGX Digital Media Switchers (DGX 8/16/32/64 

and DGX 100 Series).

 

 

Attaching Cable Management Bars

 

Items included in Sales # FG1056-700 (Cable Bar Kit only) and in Cable Bar Kit # KA1056-700 (which ships with SC Optical and 

DXLink Fiber Boards):

 

 

1 cable management bar

 

 

4 screws (3 required)

 

When cable management bars are used, they need to be installed before the cables are attached.

 

CAUTION: 

Do 

not 

severely bend or kink the fiber optic cable. Irreversible damage can occur. Refer to the physical limitations (bend 

radius) specified for the cable by the manufacturer.

 

To install a cable management bar:

 

1.

 

32x32 size enclosures only 

– Loosen the two captive screws that hold the connector numbering plate at the top of the 

connectors. Remove the connector numbering plate and set aside.

 

Connector numbering plate

 

 
 
 

FIG. 1 

Connector numbering plate (Epica DGX 32 shown)

 

2.

 

Align the two screw holes on the end of the cable management bar with the two screw holes on the end of the board as shown 

in FIG. 2. (Note the position of the long part of the bar in relation to the screw holes.)

 

Epica DGX 32, Enova DGX 32, Enova DGX 3200

 

Fasten cable management bar with 

two screws on one end and one on 

the other end (do 

not 

over tighten)

 

 

Tie cable to cable management 

bar far enough from connector to 

allow for manufacturer’s 

recommended bend radius

 

 
 
 
 

 

Epica DGX 16, Enova DGX 8/16/64, Enova DGX 800/1600/6400

 

NOTE: 

On Epica DGX 16, Enova DGX 8/16/64, and Enova DGX 800/1600/6400 enclosures, the orientation of the cable 

management bars is reversed from boards in the left slots to boards in the right slots

.

 

Board in left slot

 

Board in right slot

 

 

FIG. 2 

Installation of cable management bars

 

3.

 

Insert and tighten the two screws at the end of the cable management bar (do 

not 

over tighten the screws).

 

4.

 

Align, insert, and tighten the single screw at the other end of the cable management bar (do 

not 

over tighten).

 

TIP: 

When using cable management bars with fiber boards, we recommend the use of soft ties (e.g., Velcro type hook-and-loop 

strips) instead of nylon cable ties, which can break fiber cables.

 

Reviews: