15
English
Connecting the TV with STB (SBB)
TV Rear Panel
Data Cable
✎
The rear panel may differ depending on the model.
• Connect the
DATA
jack of the TV to the [ETH MODEM] jack of the STB (SBB) with the Data cable.
✎
Use data communication.
• IR signals sent by the remote control to the TV or SBB / STB must meet the following specification to use IR pass
through function.
IR signal receiver specification
‒ Band pass filter centre frequency: 37.9
㎑
‒ Carrier Frequency, Duty 50%
‒ Minimum Burst Length (tburst): 12 pulses (316 us)
‒ Minimum Gap Time Between the burst (tburst gap): 16 pulses (422 us)
‒ Minimum Gap Time between the data commands (tpause): 25
㎳
¦
List of Vendors and Compatible Data Cables Supplied with the TV
• Confirm that you are using the correct data cable for your vendor. Refer to the code label on the data cables.
CON A
CON B
6
1
1
6
STB SIDE
TV SIDE
CON B
1: NC
2: GND
3: Rx
4: NC
5: Tx
6: IR
6: NC
5: IR
4: GND
3: Rx
2: Tx
1: Nc
CON A
CON B
CON A
5
6
4
2
3
5
2
3
✎
Operation Specification of Data Cable(RJ12) : RS232