iDCS 100
INSTALLATION
TECHNICAL MANUAL
PART 11 JUNE 2002
11.1
PART 11. ADDING CARDS TO AN EXISTING
SYSTEM
11.1 ADDING AN SMISC CARD
1. Check the battery switch on the MEM3 or MEM4 card and make sure it is ON.
2. Turn off power to the system and unplug the power cord.
3. Insert the SMISC2 card into the slot labeled MISC.
4. Restore power to the system.
5. Open system programming and use
to assign directory numbers to the ports on the card. The port
numbers and recommended directory numbers are listed in the table below. These
directory numbers are the same as the numbers that would have been assigned
when the system was first installed.
ITEM
PORT NUMBER
DIRECTORY NUMBER
AA PORT 1
023
381
AA PORT 2
024
382
AA PORT 3
025
383
AA PORT 4
026
384
MOH/BGM 2
027
372
PAGE OUTPUT 2
028
362
RELAY 1
029
363
RELAY 2
030
364
RELAY 3
031
365
ALARM SENSOR
032
352
11.2 ADDING A 2 SLI CARD
1. Check the battery switch on the MEM3 or MEM4 card and make sure it is ON.
2. Turn off power to the system and unplug the power cord.
3. Insert the 2 SLI card into the slot labeled SLI.
4. Restore power to the system.
5. Open system programming and use
to assign directory numbers to the ports on the card. The port
numbers for the 2 SLI are listed in the following table.