KS57C2308/P2308/C2316/P2316
OSCILLATOR CIRCUITS
6-9
Table 6-5. System Operating Mode Comparison
Mode
Condition
STOP/IDLE Mode Start
Method
Current
Consumption
Main operating mode
Main oscillator runs.
Sub oscillator runs (stops).
System clock is the main
oscillation clock.
–
A
Main Idle mode
Main oscillator runs.
Sub oscillator runs (stops).
System clock is the main
oscillation clock.
IDLE instruction
B
Main Stop mode
Main oscillator runs.
Sub oscillator runs.
System clock is the main
oscillation clock.
STOP instruction
D
Sub operating mode
Main oscillator is stopped by
SCMOD.3.
Sub oscillator runs.
System clock is the sub
oscillation clock.
–
C
Sub ldle Mode
Main oscillator is stopped by
SCMOD.3.
Sub oscillator runs.
System clock is the sub
oscillation clock.
IDLE instruction
D
Sub Stop mode
Main oscillator is stopped by
SCMOD.3.
Sub oscillator runs.
System clock is the sub
oscillation clock.
Setting SCMOD.2 to “1”
This mode can be released
only by an external reset.
E
Main/Sub Stop mode
Main oscillator runs.
Sub oscillator is stopped by
SCMOD.2.
System clock is the main
oscillation clock.
STOP instruction:
This mode can be released
by an interrupt and reset.
E
NOTE
: The current consumption is: A > B > C > D > E.
Summary of Contents for KS57C2308
Page 30: ...ADDRESS SPACES KS57C2308 P2308 C2316 P2316 2 22 NOTES ...
Page 168: ...SAM47 INSTRUCTION SET KS57C2308 P2308 C2316 P2316 5 94 NOTES ...
Page 170: ......
Page 206: ...POWER DOWN KS57C2308 P2308 C2316 P2316 8 8 NOTES ...
Page 210: ...RESET KS57C2308 P2308 C2316 P2316 9 4 NOTES ...
Page 222: ...I O PORTS KS57C2308 P2308 C2316 P2316 10 12 NOTES ...
Page 272: ...LCD CONTROLLER DRIVER KS57C2308 P2308 C2316 P2316 12 24 NOTES ...
Page 280: ...SERIAL I O INTERFACE KS57C2308 P2308 C2316 P2316 13 8 NOTES ...
Page 294: ...MECHANICAL DATA KS57C2308 P2308 C2316 P2316 15 2 NOTES ...
Page 310: ...KS57P2308 P2316 OTP KS57C2308 P2308 C2316 P2316 16 16 NOTES ...
Page 318: ......
Page 320: ......
Page 322: ......
Page 325: ......
Page 327: ......