Page 1: ...ENGLISH ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH USER SMANUAL FunctionController MCM A100 System Air Conditioner DB98 27317A 1 S E F I D P G R A EΛΛHNIKA RUSSIAN ...

Page 2: ...roller Must install the function controller with rated power supply In the event of a malfunction burning smell etc immediately stop operation turn off the electrical breaker and consult authorized service personnel CAUTION Do not use inflammable gases near the function controller Do not spill water into the function controller Do not operate the function controller with wet hands Do not install t...

Page 3: ...4 GETTING START 5 SELECTING THE INDOOR UNIT 6 SELECTING THE AUTOMATIC OPERATING MODE 7 COOLING YOUR ROOM 8 HEATING YOUR ROOM EXCEPT COOLING ONLY MODELS 10 REMOVING EXCESS HUMIDITY 12 AIRING YOUR ROOM 14 ADJUSTING THE AIR FLOW DIRECTION EXCEPT DUCT TYPE 15 ...

Page 4: ...cept Cooling Only Models Temperature setting Fan speed Air flow direction On Off Timer Set Cancel button Fan speed adjustment button On Off indicator Operating mode Centralized controller indicator Note Test button is for your installation specialist You must NOT press it After cleaning the air filter press the filter reset button Then the function controller will display the FILTER SIGN indicator...

Page 5: ...ns much valuable information on using your function controller Please take time to read as it will help you take full advantage of the unit s features In the main part of the document you will find a series of step by step procedures for each function available The illustrations in the step by step procedures use three different symbols PRESS PUSH HOLD DOWN ...

Page 6: ...on by pressing ON OFF button Result The On Off indicator on the function controller comes on The air conditioner runs in the mode selected when the unit was last used 3 Select an appropriate operating mode by pressing Mode button Result The air conditioner runs in the selected mode Note For further details on operating modes refer to page 7 15 Selecting the Indoor Unit You can control a specific i...

Page 7: ...ed in Stopped lt will start up normally after three minutes 2 To select the AUTO mode press the Mode button until is displayed at the top of the function controller Result The air conditioner runs in AUTO mode Note You can change modes at any time 3 To adjust the temperature press theTemperature buttons one or more times until the required temperature is displayed Possible temperatures are between...

Page 8: ... the mode selected when the unit was last used Caution The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped lt will start up normally after three minutes 2 To select the COOL mode press the Mode button until is displayed at the top of the function controller Result The air conditioner runs in ...

Page 9: ...time you press Temperature buttons The temperature is adjusted by 1 C 1 F The air conditioner starts cooling provided that the room temperature is higher than the selected temperature the fan will however operate 4 Select the fan speed by pressing the Fan button one or more times until the intended value is displayed Automatic rotated Low Medium High 5 To control the direction of the air flow refe...

Page 10: ...ected when the unit was last used Caution The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped lt will start up normally after three minutes 2 To select the HEAT mode press the Mode button until is displayed at the top of the function controller Result The air conditioner runs in HEAT mode Not...

Page 11: ... time you press Temperature buttons The temperature is adjusted by 1 C 1 F The air conditioner starts cooling provided that the room temperature is higher than the selected temperature the fan will however operate 4 Select the fan speed by pressing the Fan button one or more times until the intended value is displayed Automatic rotated Low Medium High 5 To control the direction of the air flow ref...

Page 12: ...ir conditioner runs in the mode selected when the unit was last used Caution The air conditioner is fitted with a protection mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped lt will start up normally after three minutes 2 To select the DRY mode press the Mode button until is displayed at the top of the function controller Result The air...

Page 13: ...isplayed Possible temperatures are between 18 C 65 F and 30 C 86 F inclusive Result Each time you press Temperature buttons The temperature is adjusted by 1 C 1 F The air conditioner starts removing the excess humidity The quantity of air is adjusted automatically 4 To control the direction of the air flow refer to page 15 ...

Page 14: ...n mechanism to prevent the unit from being damaged when it is started immediately after being Plugged in Stopped lt will start up normally after three minutes 2 To select the FAN mode press the Mode button until is displayed at the top of the function controller Result The air conditioner runs in FAN mode Note You can change modes at any time 3 Select the fan speed by pressing the Fan button one o...

Page 15: ...ow blade thus increasing the efficiency of the air conditioner 1 Press the Swing button Result The blade is moving up and down Caution When the air conditioner is first turned on the blade is moved 2 To stop the blade press the Swing button again To set to the required position press the Swing button again when the blade is in the required position ...