background image

Installation Instructions

Over The Range Microwave Oven

BEFORE YOU BEGIN

 (Read these instructions completely and carefully.)

IMPORTANT

Save these instructions for local inspector’s use.

IMPORTANT

Observe all governing codes and ordinances.

•  Note to Installer 

-  Be sure to leave these instructions with the Consumer.

•  Note to Consumer 

-  Keep these instructions for future reference.

•  Skill level 

-  Installation of this appliance requires basic mechanical and electrical 

skills.

•  Proper installation is the responsibility of the installer.
•  Product failure due to improper installation is not covered under the Warranty.

READ CAREFULLY. KEEP THESE INSTRUCTIONS.

This manual is made with 100% recycled paper.

SMH1927_XAC_DE68-04108B-01_EN-120725.indd   1

2012-07-25   �� 7:56:29

Summary of Contents for ME21M706BAG/AC

Page 1: ...hese instructions with the Consumer Note to Consumer Keep these instructions for future reference Skill level Installation of this appliance requires basic mechanical and electrical skills Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Warranty READ CAREFULLY KEEP THESE INSTRUCTIONS This manual is made with 100 recyc...

Page 2: ...g the microwave blower for recirculation 12 B2 Installing the charcoal filter 13 C Outside back exhaust horizontal duct 14 C1 Adapting the microwave blower for outside back exhaust 14 3 Installation 15 A Preparing the rear wall for outside back exhaust 15 B Attach the mounting plate to the wall 15 C Use the top cabinet template to prepare the top cabinet 16 D Mount the microwave oven 16 E Connecti...

Page 3: ...oper ground exists before use Insure proper ground exists before use The power cord of this appliance is equipped with a three prong grounding plug which mates with a standard three prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance You should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is...

Page 4: ...ar to round transition adaptor is used the bottom corners of the damper will have to be cut to fit using the tin snips in order to allow free movement of the damper OUTSIDE BACK EXHAUST EXAMPLE ONLY The following chart contains an example of one possible ductwork installation DUCT PIECES EQUIVALENT LENGTH x NUMBER USED EQUIVALENT LENGTH Wall Cap 40 ft x 1 40 ft 3 Ft Straight Duct 3 x 10 Rectangula...

Page 5: ...aps etc present additional resistance to airflow and are equivalent to a section of straight duct which is longer than their actual physical size When calculating the total duct length add the equivalent lengths of all transitions and adaptors plus the length of all straight duct sections The chart below shows you how to calculate total equivalent ductwork length using the equivalent length in fee...

Page 6: ...ALLATION INSTRUCTIONS Wood Screws x 2 1 Template INSTALLATION INSTRUCTIONS Toggle Bolts and wing nuts 3 16 x 3 2 Template INSTALLATION INSTRUCTIONS Self aligning Machine Screws 28 x 3 2 You will find the installation hardware contained in a packet with the unit Check to make sure you have all these parts NOTE Some extra parts are included ADDITIONAL PARTS PART QUANTITY TOP CABINET TEMPLATE REAR WA...

Page 7: ... NOTES The space between the cabinets must be 30 wide and free of obstructions This microwave oven is for installation over ranges up to 36 wide If you are going to vent your microwave oven to the outside see the Hood Exhaust Section for exhaust duct preparation If installing the microwave oven beneath smooth flat cabinets be careful to follow the instructions on the top cabinet template for power...

Page 8: ...rews from the mounting plate This plate will be used as the rear wall template and for mounting NOTE You will have to reuse two screws in original loction of outcase after removing mounting plate B Finding the wall studs Wall Studs Center Center Wall Studs 1 Find the studs using one of the following methods A Stud finder a magnetic device which locates nails OR B Use a hammer to tap lightly across...

Page 9: ... with front overhang Draw a line on the back wall equal to the depth of the front overhang 30 to Cooktop Plate position beneath recessed bottom cabinet with front overhang 30 to Cooktop Draw a horizontal line to mark how far the inside of the front overhang descends below the cabinet Your cabinets may have decorative trim that interferes with the microwave installation Remove the decorative trim t...

Page 10: ...ingers on sharp edges 1 Draw a Horizontal line on the wall at the bottom of the Rear Wall Template 2 Drill holes for toggle bolts in 3 locations Hole A Hole B Hole C as shown in the illustration above If the location of a hole lines up with a stud drill a 3 16 hole for a wood screw You cannot use a toggle bolt to attach the wall plate to a stud NOTE DO NOT MOUNT THE PLATE AT THIS TIME 3 Holes A B ...

Page 11: ...haust adaptor is shipped assembled and attached to the filler upper Select the type of ventilation required for your installation and proceed to that section A Outside top exhaust vertical duct B Recirculating non vented ductless Adaptor in Place for Outside Top Exhaust Adaptor in Place for Outside Top Exhaust See page 12 See page 13 A Charcoal Filter Accessory Kit is required for the nonvented ex...

Page 12: ...you have installed the microwave you will need to open the top cabinet and adjust the exhaust adaptor so that you can connect it to the house duct For Front to Back Adjustment Slide the Exhaust Adaptor as Needed Blower Plate Back of Microwave Damper NOTE You must attach the house duct to the exhaust adaptor after installation is complete House Duct House Duct B Recirculating non vented ductless B1...

Page 13: ...ore Roll After Roll Back of Microwave 5 Place the blower unit back into the opening CAUTION Do not pull or stretch the blower unit wiring Make sure the wires are not pinched 6 Secure the blower unit to the microwave with the screw B2 Installing the charcoal filter 1 Remove the screws on the top of the grill using a 1 Phillips screwdriver 2 Open the door 3 Remove the grill Push the grill left and t...

Page 14: ...unterclockwise 180 Before Rotation After Rotation Back of Microwave Back of Microwave 6 Place the blower unit back into the opening AFTER Fan Blade Openings Facing Back End B End A CAUTION Do not pull or stretch the blower unit wiring Make sure the wires are not pinched NOTE The blower unit exhaust openings should match exhaust openings on the rear of microwave oven 7 Close the Blower Plate and at...

Page 15: ...ontal duct only B Attach Mounting Plate to Wall C Prepare Top Cabinet D Mount the Microwave Oven E Connecting Ductwork vertical duct only A Preparing the rear wall for outside back exhaust You need to cut an opening in the rear wall for outside exhaust C L Read the instructions for outside back exhaust on the REAR WALL TEMPLATE Tape the REAR WALL TEMPLATE to the rear wall Cut the opening following...

Page 16: ...instructions on the TOP CABINET TEMPLATE Tape it underneath the top cabinet Drill the holes following the instructions on the TOP CABINET TEMPLATE CAUTION Wear safety goggles when drilling holes in the cabinet bottom D Mount the microwave oven FOR EASIER INSTALLATION AND PERSONAL SAFETY WE RECOMMEND THAT TWO PEOPLE INSTALL THIS MICROWAVE OVEN IMPORTANT Do not grip or use the handle during installa...

Page 17: ...Bottom Shelf Equivalent to Depth of Cabinet Recess Cabinet Bottom Shelf Microwave Oven Top Cabinet Front Filler Block Self Aligning Screw 4 Attach the microwave oven to the top cabinet 5 Insert the 2 self aligning screws through the cabinet bottom shelf and filler block into the outer top cabinet of the unit Continue to support the unit until both screws are inserted and engaged at least two full ...

Page 18: ...lace the house fuse or turn the breaker back on Insure proper ground exists before use 5 Plug the power cord into a dedicated 15 amp electrical outlet Insure proper ground exists before use Insure proper ground exists before use 6 Read the Owner s Manual 7 Keep installation instructions for the local inspector s use 4 Before you use your microwave SMH1927_XAC_DE68 04108B 01_EN 120725 indd 18 2012 ...

Page 19: ...19 Note SMH1927_XAC_DE68 04108B 01_EN 120725 indd 19 2012 07 25 7 56 39 ...

Page 20: ...Code No DE68 04108B 01 SMH1927_XAC_DE68 04108B 01_EN 120725 indd 20 2012 07 25 7 56 39 ...

Page 21: ...ctions à l utilisateur Remarque destinée à l utilisateur Conservez précieusement ces instructions en vue d une consultation ultérieure Niveau de compétences L installation de cet appareil nécessite des connaissances mécaniques et électriques de base Il incombe à l installateur de poser correctement l appareil Tout dysfonctionnement imputable à une mauvaise installation n est pas couvert par la gar...

Page 22: ...cro ondes à la circulation en circuit fermé 12 B2 Installation du filtre à charbon 13 C Système d évacuation par l arrière conduit horizontal 14 C1 Adaptation du ventilateur du four micro ondes au système d évacuation par l arrière 14 3 Installation 15 A Préparation du mur du fond pour le système d évacuation par l arrière 15 B Fixation de la plaque murale 15 C Utilisation du gabarit du meuble hau...

Page 23: ...D ÉLECTROCUTION Insure proper ground exists before use Assurez vous que le four est correctement mis à la terre avant de l utiliser Le cordon d alimentation de cet appareil est équipé d une prise tripolaire mise à la terre correspondant à la prise murale tripolaire standard mise à la terre afin de réduire le risque d électrocution Faites vérifier la prise murale et le circuit par un électricien qu...

Page 24: ... adaptateur rectangulaire circulaire est utilisé les coins inférieurs du registre devront être coupés à l aide de cisailles afin de le fixer et de permettre au registre de bouger librement SYSTÈME D ÉVACUATION PAR L ARRIÈRE EXEMPLE UNIQUEMENT Le tableau suivant contient un type d installation de conduits possible COMPOSANTS DE L ÉVACUATION LONGUEUR ÉQUIVALENTE x NOMBRE UTILISÉ LONGUEUR ÉQUIVALENTE...

Page 25: ...istance supplémentaire à la circulation de l air et sont équivalents à une partie de conduit droit plus long que leur véritable taille Lors du calcul de la longueur totale du conduit ajoutez les longueurs équivalentes de tous les raccords et adaptateurs à la longueur de toutes les parties de conduit droit Le tableau suivant vous indique comment calculer la longueur équivalente totale des conduits ...

Page 26: ...1 Template INSTALLATION INSTRUCTIONS Boulons à ailettes et écrous à oreilles 3 16 x 3 2 Template INSTALLATION INSTRUCTIONS Vis mécaniques autocentreuses 28 x 3 2 L appareil est livré avec un sachet contenant le matériel d installation Vérifiez que vous disposez de toutes ces pièces REMARQUE certaines pièces supplémentaires sont incluses PIÈCES SUPPLÉMENTAIRES PIÈCE QUANTITÉ TOP CABINET TEMPLATE RE...

Page 27: ... doit être de 30 et dégagé Ce four micro ondes est conçu pour être installé au dessus d une cuisinière de 36 de large Si vous souhaitez utiliser un système de ventilation pour le four micro ondes reportez vous à la partie Système d évacuation de la hotte pour la préparation du conduit d évacuation Lors de l installation du four micro ondes sous un meuble plat et lisse respectez les instructions fi...

Page 28: ...omme gabarit du mur du fond et pour le montage REMARQUE vous devrez réutiliser deux vis à leur emplacement d origine sur le châssis une fois la plaque de fixation retirée B Détection des montants Wall Studs Center Centre Montants 1 Recherchez les montants en utilisant l une des méthodes suivantes A Détecteur de montant appareil magnétique qui localise les clous OU B Utilisez un marteau pour frappe...

Page 29: ...s un meuble encastré avec débord frontal 30 de la surface de cuisson Tracez une ligne horizontale afin de marquer la distance dont la partie intérieure du débord frontal descend sous le meuble Si le meuble sur lequel vous souhaitez fixer l appareil comporte des ornements décoratifs ces derniers risquent de gêner l installation Retirez ces ornements pour assurer une installation et une mise à nivea...

Page 30: ...mur 2 Percez des trous de pour les boulons à ailettes à 3 emplacements trou A trou B trou C comme indiqué sur l illustration ci dessus Si l emplacement d un trou est aligné sur un montant percez un trou de 3 16 en vue de la pose d une vis à bois Les boulons à ailettes ne peuvent être utilisés pour fixer la plaque murale à un montant REMARQUE NE POSEZ PAS ENCORE LA PLAQUE À CETTE ÉTAPE DU MONTAGE 3...

Page 31: ... et fixé à la cale supérieure Sélectionnez le système de ventilation adapté à votre installation et reportez vous à la section correspondante A Système d évacuation par le haut conduit vertical B Circulation de l air en circuit fermé sans conduit et sans évents Adaptor in Place for Outside Top Exhaust Emplacement de l adaptateur pour une évacuation par le haut Reportez vous à la page 12 Reportez v...

Page 32: ...daptateur du système d évacuation afin de le relier au conduit de l habitation Pour un réglage avant arrière faites glisser l adaptateur du système d évacuation autant que nécessaire Plaque du ventilateur Arrière du micro ondes Registre REMARQUE vous devez fixer le conduit de l habitation à l adaptateur du système d évacuation après avoir terminé l installation House Duct Conduit de la cuisine B C...

Page 33: ...u micro ondes 5 Remettez le ventilateur dans son logement ATTENTION ne tirez pas sur les câbles du ventilateur Assurez vous que les câbles n ont pas été coincés au moment de la remise en place 6 Fixez le ventilateur sur le four micro ondes à l aide de la vis B2 Installation du filtre à charbon 1 Retirez les vis de la partie supérieure de la grille à l aide d un tournevis cruciforme nº 1 2 Ouvrez l...

Page 34: ...ntre Avant la rotation Après la rotation Arrière du micro ondes Arrière du micro ondes 6 Remettez le ventilateur dans son logement APRÈS ouvertures des ailettes du ventilateur dirigées vers l arrière Extrémité B Extrémité A ATTENTION ne tirez pas sur les câbles du ventilateur Assurez vous que les câbles n ont pas été coincés au moment de la remise en place REMARQUE Les ouvertures du système d évac...

Page 35: ...ge du four micro ondes E Connexion des conduits conduit vertical uniquement A Préparation du mur du fond pour le système d évacuation par l arrière Vous devez pratiquer une ouverture dans le mur du fond pour installer le système d évacuation C L Lisez les instructions relatives au système d évacuation par l arrière figurant sur le GABARIT DU MUR DU FOND Fixez le GABARIT DU MUR DU FOND au mur arriè...

Page 36: ... pour y faire passer le cordon d alimentation Lisez les instructions figurant sur le GABARIT DU MEUBLE HAUT Collez le sous le plancher du meuble haut Percez les trous en respectant les instructions figurant sur le GABARIT DU MEUBLE HAUT ATTENTION portez des lunettes de sécurité pendant cette dernière opération D Montage du four micro ondes POUR PLUS DE FACILITÉ ET DE SÉCURITÉ LORS DE L INSTALLATIO...

Page 37: ...nt Filler Block Microwave Oven Top Self Aligning Screw Equivalent to Depth of Cabinet Recess Cabinet Bottom Shelf Equivalent à l enfoncement du meuble Fond du meuble Haut du four micro ondes Avant du meuble Cale Vis autocentreuse 4 Fixez le four micro ondes sur le meuble haut 5 Insérez 2 vis autocentreuses à travers le fond du meuble et des cales dans les trous extérieurs du meuble haut de l unité...

Page 38: ...ur sous tension Insure proper ground exists before use 5 Branchez le cordon d alimentation sur une prise dédiée de 15 A Insure proper ground exists before use Assurez vous que le four est correctement mis à la terre avant de l utiliser 6 Lisez le manuel d utilisation 7 Conservez précieusement ces instructions d installation afin que la personne chargée du contrôle local puisse s y reporter 4 Avant...

Page 39: ...19 Remarque SMH1927_XAC_DE68 04108B 01_CFR_120725 indd 19 2012 07 25 7 57 54 ...

Page 40: ...N de code DE68 04108B 01 SMH1927_XAC_DE68 04108B 01_CFR_120725 indd 20 2012 07 25 7 57 54 ...

Reviews: