background image

Air Source Heat Pump

Handover and Maintenance Log Book

Model Numbers

MIM-E03 A and B N

AE 050-090-120-140-160JXYDEH

Summary of Contents for MIM-E03 A

Page 1: ...Air Source Heat Pump Handover and Maintenance Log Book Model Numbers MIM E03 A and B N AE 050 090 120 140 160JXYDEH ...

Page 2: ...anty covering only the Samsung components The Samsung warranty covers parts only Any labour charges for replacing faulty parts are not covered Your installer may offer you a full parts labour and call out warranty as part of their maintenance agreement but you need to discuss this with the installer maintenance company The Samsung warranty does not cover radiators cylinders UFH valves pumps etc It...

Page 3: ...ich looks like this you should not use this or press the buttons it is used for commissioning and fault diagnosing the system only On Youtube search for freedom heat pumps there are videos showing how to use the controller faults etc Normally the controller will show AU or 0 0c on the left and a tap in the right hand top corner This is normal it means the system is controlled by external thermosta...

Page 4: ...oks like when the unit is running in Hot Water Mode Overview of the Samsung Controller The outing mode button sets the hot water cylinder temperature to 25 C but has no effect on heating this is ideal for when you go away on holiday etc If you turn all thermostats down as well the heat pump won t run which will save money The Silent mode button is not used due to risk of freezing up etc Location F...

Page 5: ...ws that the Immersion heater is running Shows that the hybrid boiler is running Hybrid systems only 9 Shows that the water circulation pump is running Shows that the hot water valve is open and the heat pump is heating the hot water cylinder Shows that the unit is in defrost mode see defrost video on you tube Shows that the unit is in freezing control mode when the outdoor temp us below 10 C the u...

Page 6: ...utside The tap is the cylinder temperature Over time the unit will warm up now check all the radiators or under floor loops are hot as well Starting the System in hot water mode Clean the filter balls Press DHW on off power button to start the unit top right button A picture of a tap appears with dots by it press Mode until 2 dots appear This means the HP will heat the water with help from the imm...

Page 7: ...the overheat thermostat is set to 70 C On a Telford cylinder set the stat to 5 Press the mode button until a bath symbol shows on the Samsung remote controller this will force the immersion heater on Check immersion heater works properly Measure the current drawn by the heater it should be 12 13 Amps Measure the temperature of the flow using the remote controller Measure the flow rate from the flo...

Page 8: ...eturn at Heat Pump Flow Rate Return from Header Flow out of Header Flow into Header Return from Heating Maintenance Form Year 3 The engineer should leave a copy of this form with the home owner as evidence of an annual service to keep up with the warranty Heating Mode Commissioning Data What type of system do you have Pre plumbed Separate Cylinder Is there a Header Buffer or Heat Exchanger install...

Page 9: ...eturn at Heat Pump Flow Rate Return from Header Flow out of Header Flow into Header Return from Heating Maintenance Form Year 5 The engineer should leave a copy of this form with the home owner as evidence of an annual service to keep up with the warranty Heating Mode Commissioning Data What type of system do you have Pre plumbed Separate Cylinder Is there a Header Buffer or Heat Exchanger install...

Page 10: ...eturn at Heat Pump Flow Rate Return from Header Flow out of Header Flow into Header Return from Heating Maintenance Form Year 7 The engineer should leave a copy of this form with the home owner as evidence of an annual service to keep up with the warranty Heating Mode Commissioning Data What type of system do you have Pre plumbed Separate Cylinder Is there a Header Buffer or Heat Exchanger install...

Page 11: ... trademarks of Samsung Electronics Co Ltd Specifications and designs are subject to change without notice Non metric weights and measurements are approximate All data were deemed correct at time of creation Samsung is not liable for errors or omissions All brand product service names and logos are trademarks and or registered trademarks of their respective owners and are hereby recognized and ackn...

Reviews: