To do list
5-1-3. Self-diagnostic function
1) Self-diagnostic function in the Initial power ON
1-1) Micom operates self-diagnostic function to check the temperature sensor condition within 1 second
when the refrigerator turned On initially.
1-2) If bad sensor is detected by the self-diagnostic function, the applicable display LED will blink for 0.5 sec.
At this moment, there is no beep sound.(Refer to self-diagnostic CHECK LIST)
1-3) Self-diagnostic button is recognized only when the error is displayed by the bad sensor. Display does
not operate normally but temperature control will be controlled by the emergency operation.
1-4) When the error is detected by self-diagnosis, the error can be canceled automatically if all troubled
sensors are corrected or Self-diagnostic function key (Energy Saver Key + Lighting Key ) are pressed
simultaneously for 8 seconds. (Return to normal display mode)
①
If Energy Saver Key + Lighting Key are pressed simultaneously
for 8 seconds, the error mode by self-diagnosis will be canceled.
5. Check the installation status
5-1. Function for failure diagnosis
RF31FM*S**(For Ice/water model Only)
RF31FM*D** / RF24FS**(For Ice/water model Only)