6-1. If the trouble is detected by self-diagnosis
6. Self Diagnosis & Trouble Shooting
To do list
Start
MAIN PCB Connector CN78
inserted correctly?
Ambient Sensor unit
normal?
YES
Bad contact of connector/
insert correctly
NO
YES
NO
4) If Ambient Sensor has trouble
Is the voltage between
MAIN PCB Connector CN78 ”8”(Yellow)
and J23 JUMMPER normal?
NO
(0.6V > Measurement < 4.6V)
Sensor MICOM/Connector number
Ambient
Connector CN78-
"8"(Yellow) to J23
JUMMPER PCB typical
Ground
Voltage measured between 4.6V ~ 0.6V.
Replace the temperature
sensor
Recheck the wiring
connection
Refer to circuit diagram in the manual
DATA1. Temperature table
** Measuring point of resistance value
according to Sensor **
Ambient : CN78#8 ↔ #12 measuring
resistance value
** Placed in the right top table of upper
hinge.
** 0Ω: Short trouble / ∞Ω: Open trouble