4. Troubleshooting
i) Check the signal and power with the DVM.
ii) If the checked result is normal, replace the BLDC motor(
JC93-00448A
).
iii) If the checked result is abnormal, check the following.
- If 24V power is not generated, replace the SMPS board (
JC44-00100C (220V) / JC44-00093C (110V)
).
- If the control signal is abnormal, replace the main board(
JC92–02746A
)
b) If the motor is operational, check the Pin Num 8.
i) If the value is abnormal, replace the main board.
ii) If the value is normal, replace the harness.
4-69