4. Troubleshooting
i) Check the signal and power with the DVM.
ii) If the checked result is normal, replace the BLDC motor(
JC31-00123B
).
iii) If the checked result is abnormal, check the following.
- If 24V power is not generated, replace the SMPS board (
JC44-00100C (220V) / JC44-00093C (110V)
).
- if the control signal is abnormal, replace the main board(
JC92–02746A
)
b) If the motor is operational, check the Pin Num 8.
i) If the value is abnormal, replace the main board.
ii) If the value is normal, replace the harness.
4-71
Copyright© 1995-2017 SAMSUNG. All rights reserved.
Summary of Contents for MultiXpress K4 Series
Page 10: ...Contents 6 4 Document Revision List 6 10 ix Copyright 1995 2017 SAMSUNG All rights reserved ...
Page 53: ...2 Product Specifications and Description Copyright 1995 2017 SAMSUNG All rights reserved 2 37 ...
Page 76: ...2 Product Specifications and Description 2 60 Copyright 1995 2017 SAMSUNG All rights reserved ...