4. Troubleshooting
Code
Display
Meaning
Default
Max/Min
112-0130 Manual Color Regi X-offset Magenta
Distant from hsync to lsync (multi-hsync)
for Magenta
100
200 / 0
112-0140 Manual Color Regi X-offset Cyan
Distant from hsync to lsync (multi-hsync)
for Cyan
100
200 / 0
112-0150 Manual Color Regi X-offset Black
Distant from hsync to lsync (multi-hsync)
for Black
100
200 / 0
112-0160 Manual Color Regi Y-offset Yellow
Distant from psync to Image area for
yellow
100
200 / 0
112-0170 Manual Color Regi Y-offset Magenta
Distant from psync to Image area for
Magenta
100
200 / 0
112-0180 Manual Color Regi Y-offset Cyan
Distant from psync to Image area for Cyan
100
200 / 0
112-0190 Manual Color Regi Y-offset Black
Distant from psync to Image area for Black
100
200 / 0
112-0200 Manual Color Regi Width Yellow
Image Area Width for Yellow
1000
2000 / 0
112-0210 Manual Color Regi Width Magenta
Image Area Width for Magenta
1000
2000 / 0
112-0220 Manual Color Regi Width Cyan
Image Area Width for Cyan
1000
2000 / 0
112-0230 Manual Color Regi Width Black
Image Area Width for Black
1000
2000 / 0
112-0240 Manual Color Regi Left Width Yellow
Image Area Left Width for Yellow
500
1000 / 0
112-0250 Manual Color Regi Right Width Yellow
Image Area Right Width for Yellow
500
1000 / 0
112-0260 Manual Color Regi Left Width Magenta
Image Area Left Width for Magenta
500
1000 / 0
112-0270 Manual Color Regi Right Width Magenta
Image Area Right Width for Magenta
500
1000 / 0
112-0280 Manual Color Regi Left Width Cyan
Image Area Left Width for Cyan
500
1000 / 0
112-0290 Manual Color Regi Right Width Cyan
Image Area Right Width for Cyan
500
1000 / 0
112-0300 Manual Color Regi Left Width Black
Image Area Left Width for Black
500
1000 / 0
112-0310 Manual Color Regi Right Width Black
Image Area Right Width for Black
500
1000 / 0
112-0320 Color Regi LSU Skew Yellow
LSU Skew for Yellow
100
200 / 0
112-0330 Color Regi LSU Skew Magenta
LSU Skew for Magenta
100
200 / 0
112-0340 Color Regi LSU Skew Cyan
LSU Skew for Cyan
100
200 / 0
Engine Test Routines
•
Diagnostics > Engine Diagnostics > Engine Test Routines
Purpose
To perform test routines for the engine.
Operation Procedure
When the main Engine Test Routines window displays, users can navigate through the list of routines
that display along with their descriptions. Users can also directly input an EDC code to the text box to
find a routine. Users can select a maximum of 3 routines at the same time.
After selecting one or multiple routines, pressing the “OK” button will open the test window that lists
selected routines. Users can start/stop a desired test routine.
Verification
N/A
Specification
N/A
Reference
N/A
4-32
Copyright© 1995-2017 SAMSUNG. All rights reserved.