4. Troubleshooting
► Error Code
A3–3310
A3–3311
A3–3312
A3–3410
A3–3411
A3–3412
► Error message
Sensor Failure: #A3-3310. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3311. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3312. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3410. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3411. Turn off then on. Call for service if the problem persists
Sensor Failure: #A3-3412. Turn off then on. Call for service if the problem persists
► Symptom
Outer temperature/humidity sensor is defective.
► Troubleshooting method
•
A3–3310 / A3–3311 / A3–3312 : Temperature function is abnormal.
•
A3–3410 / A3–3411 / A3–3412 : Humidity function is abnormal.
1) Remove the left cover.
(
Refer to 3.3.4 Temperature Sensor
)
Unplug and reconnect the sensor harness. If the error persists, replace the sensor(
JC93-00486A
).
2) If the harness and sensor are normal, replace the main board (
JC92-02742A
).
Copyright© 1995-2017 SAMSUNG. All rights reserved.
4-101