ENGLISH-15
0
4
O
THERS
Outing
Outing function keeps minimum cooling/heating temperature of indoor on your absence.
1. Press
the
[ Outing ]
button.
- Outing indicator will be displayed.
2. When an air conditioner is turned off,
- If indoor temperature has 5
°C(9 °F) difference with desired outing temperature, the air conditioner will be turned on
automatically.
- If indoor temperature is same as desired outing temperature, the air conditioner will be turned off automatically.
- it is repeated depending on indoor temperature within 12 hours, and then outing function is canceled.
Auto
will blink.
Cool
Outing
p
Cancel is repeated.
Dry
will blink.
Fan
will blink.
Heat
Outing
p
Cancel is repeated.
t
You can use outing function in only cool/heat mode.
t
The outing function will be active when wired remote controller is turned off.
t
The outing function operates with low fan speed.
t
If there is any input button on your wired remote controller, outing function will be canceled.
t
If your indoor unit's status is changed, outing function will be canceled.
t
You can set the desired outing temperature on the user setting mode.
<Temperature setting range>
- Cool mode : 25~30 °C (77~86 °F), default : 27 °C (81 °F)
- Heat mode : 16~22 °C (61~72 °F), default : 16 °C (61 °F)
t
You can use the outing function in the master wired remote controller. The slave wired remote controller just
displays it for a outing function status of the master wired remote controller.
- Press the
[ Outing ]
button on the slave wired remote controller, then the
will blink.
t
The outing function operation will be canceled if you change the master/slave setting on your wired remote
controller.
NOTE
5 °C difference between indoor temperature
and outing setting temperature
After 12 hr