STEP 3. INSTALLING THE POWER CORD
For power cord installations, hook the strain relief over the power cord hole (1
3
/
8
") located below
the rear of the drawer body. Insert the power cord through the strain relief and tighten the device.
Strain relief
Power cord
Conduit connection plate
•
You must install the power cord with a strain relief.
• Attach the strain relief to the 1
3
/
8
" opening in the conduit connection plate.
Installing a 3-wire power cord
WARNING
WARNING
The neutral or ground wire of the power cord must be connected to the
neutral terminal located in the center of the terminal block. The power leads must be connected to the
lower left and the lower right terminals of the terminal block.
1.
Remove the 3 lower terminal screws from the
terminal block.
2.
Insert the 3 terminal screws through each
power cord terminal ring and into the lower
terminals of the terminal block. Be certain that
the center wire (white/neutral) is connected to
the center lower position of the terminal block.
3.
Tighten screws securely to the terminal
block.
DO NOT remove the ground strap
connection.
4.
Go to
step 5
on page 26 to continue with the
installation.
Ground strap
Neutral
terminal
Black
White
Red
Black
White
Red
Live 1
Live 2
CAUTION
CAUTION
You must check voltage after connecting power cord.
Live 1 - Neutral
120 V
Live 2 - Neutral
120 V
Live 1 - Live 2
208 V / 240 V
English - 24