SURF
A
CE COOKING
Installing a 4-wire conduit
• Aluminum building wire may be used but it must be rated for the correct amperage and voltage to make the connection.
Connect the wires as described below.
• The wire you use, the location and enclosure of splices, etc., must conform to good wiring practices and local codes.
1
. Loosen the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them.
2
.
Cut and discard the ground strap. Do not discard any screws.
3
. Insert the ground bare wire tip between the range frame and the ground plate (removed earlier) and secure it in
place with the ground screw (removed earlier).
4
. Insert the bare wire (white/neutral) tip through the bottom center of the terminal block opening.
5
. Insert the two side bare wire tips into the lower left and the lower right terminal block openings.
6
. Tighten the screws until the wire is firmly secured (35 to 50 inch-lbs.). Do not over-tighten the screws since it could
damage the wires.
7
. Go to
step 5
below to continue with the installation.
Ground strap
Ground plate
White
Black
Red
Neutral
terminal
Ground
wire
(Green)
Wire tips
White
Black
Red
Live 2
Live 1
CAUTION
CAUTION
You must check voltage after connecting power cord.
Live 1 - Neutral
120 V
Live 2 - Neutral
120 V
Live 1 - Live 2
208 V / 240 V
STEP 5. REPLACING THE ACCESS COVER
To replace the rear access cover on the range back. Insert the double projections on the bottom of the cover into the
pockets located below the opening, and then insert and tighten the rear access cover screw.
English - 27
03
CONNEC