62
4. Troubleshooting
4-1-14
Troubleshooting(CE)
Check terminal block voltage.
(240V,60Hz)
UART communication Error
(CE)
Check the wiring.
(status of wiring connection)
Check the voltage of PCB , SMPS
Check the registance of each IGBT
(refer to 55page and 56 page)
Replace the Assy inverter
module PCB
- Input : 240V ( L1.L2)
- Output (inverter pcb R)
: 12V ( CN101 , 8 pin)
: 5 V ( CN101 , 6 pin)
Check the Fuse connected on
Inverter PCB.
Replace the defected PCB.
Replace the fuse.
Check the terminal block connections.
Check the circuit breaker.
Replace or Repair the wiring.