3. Disassembly and Reassembly
3-2 Removing Regulator-Energy
WARNING
Disconnect power before servicing the range Replace all panels before operating range. Failure to do so
can result in dearh or electrical shock.
PRECAUTION
When you work on the electric range, be careful when handling the sheet metal parts. Sharp edges may
be present, and you can cut yourself if you are not careful.
Parts
Explanation Photo
Explanation
Regulator-
Energy
1.
Turn off the electrical supply going
to the range.
2.
Pull the range away from the wall
so that you can access the rear
panel.
3.
Remove Cover-Back Guard Wire.
(See step 4 on page 10)
4.
Remove Regulator-Energy
connectors.
5.
Pull out the Knob-Dial.
2 Screws
6.
Remove 2 screws and replace
Regulator-Energy.
* Reassembly of All part is the reverse order of disassembly.
Screw
- Terminal Block Screw : M4 X 18.
- The others : M4 X 12.