English
7
Installation Instructions
Installation Instructions
We recommend that a qualified technician install the range hood. It is
the installer’s responsibility to ensure the range hood complies with the
installation clearances specified for the product.
•
It is recommended that the vent system be installed before the hood is
installed.
•
If possible, disconnect and move freestanding or slide-in ranges from
cabinet openings to provide easier access to the rear wall.
•
Before making cutouts, make sure there is proper clearance within the
ceiling or wall for the exhaust vent.
•
Confirm that all installation parts have been removed from the
shipping carton.
1.
Turn off the power at the circuit breaker panel or fuse box.
2.
Determine which venting method to use: roof, wall, or non-vented
(recirculating).
3.
Select a flat surface for assembling the range hood.
Place a covering over that surface.
Venting Methods
Outside Top exhaust
Use 3
1
⁄
4
" x 10" (8.3 x 25.4 cm) rectangular with a maximum vent length of
35 ft (10.7 m) or 7" (17.8 cm) or larger round vent with a maximum length
of 50 ft (15.2 m) for vent system.
Use the diagram or the hood as a template and mark the locations for the
ductwork, electrical wiring and keyhole screw slots.
D
C
CL
E
FRONT OF THE HOOD
WALL
B
A
(3.95 cm)
1
1
⁄
2
”
7” (17.8 cm)
” (8.3 cm)
10” 25.4 cm
3
1
⁄
4
A
24″ (61 cm)
B
18
7
⁄
8
″ (48 cm)
C
1″ (2.5 cm)
D
1⅞″ (4.6 cm)
E
9″ (22.8 cm)
Rear Installation Diagram
Use 31/4" x 10" (8.3 x 25.4 cm) rectangular with a maximum vent length
of 35 ft (10.7 m) for vent system.
Use the diagram or the hood as a template and mark the locations for the
ductwork, electrical wiring and keyhole screw slots.
CL
J
I
G
H
F
F
K
C
L
E
TOP OF
THE HOOD
B
A
D
A
24″ (61 cm)
B
11
9
⁄
16
″ (29.4 cm)
C
1
1
⁄
16
″ (2.7 cm)
D
3
5
⁄
8
″ (9.2 cm)
E
5
⁄
8
″ (.63 cm)
F
1
11
⁄
16
″ (4.2 cm)
G
5
5
⁄
16
″ (13.5 cm)
H
10″ (25.4 cm)
I
3
3
⁄
8
″ (8.6 cm)
J
3
9
⁄
16
″ (9.1 cm)
K
7
⁄
8
″ (2.2 cm)
L
1
1
⁄
8
″ (2.9 cm)
Installation Instructions