4 English
Ins
tallation R
equir
ement
s
Installation Requirements
Important Safety Instructions
Venting Methods
To use the hood’s top outlet to vent your hood, a 6" (15.2 cm) round vent system is
required. To use the hood’s rear outlet, a 31⁄4" x 10" (8.25 x 25.4 cm) rectangular
vent system is required. Neither of these vent systems are included and must be
purchased separately.
NOTE
Flexible vents are not recommended. Flexible vents create back pressure and air
turbulence that greatly reduces performance. The vent system can terminate either
through the roof or a wall. To vent through a wall, a 90 ° elbow is needed.
Mounting Height
Select a mounting height between a minimum of 24" (61 cm) for an electric
cooking surface, a minimum of 27" (68.6 cm) for a gas cooking surface, and a
suggested maximum of 36" (91.4 cm) above the range to the bottom of the hood.
Rear discharge
A 90 ° elbow may be installed immediately above the hood.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood can
be used in the non-vented (recirculating) version, fitting a charcoal filter and a
plastic grid. Fumes and vapors are recycled through the recirulation grid.
General Specifications
11
7
/
32
" (28.5 cm)
13
45
/
64
" (34.8 cm)
2
11
/
64
" (5.5 cm)
19
11
/
16
" (50.0 cm)
Vent Mode (Extension Kit)
Min 40" (101.6 cm)
Max 71
7
/
64
" (180.6 cm)
Vent Mode
Min 25
7
/
16
" (64.6 cm)
Max 41
31
/
32
" (106.6 cm)
Recirculation Mode (Extension Kit)
Min 41
47
/
64
" (106.0 cm)
Max 72
7
/
16
"(184.0 cm)
Recirculation Mode
Min 28
11
/
32
" (72.0 cm)
Max 44
31
/
64
" (113.0 cm)
30" NK30CB700W** (29
27
/
32
" = 75.8 cm)
30" NK30CB600W** (29
29
/
64
" = 74.8 cm)
36" NK36CB700W** (35
23
/
64
" = 89.8 cm)
36" NK36CB600W** (35
23
/
64
" = 89.8 cm)
22
37
/
32
"
(55.5 cm)
MANUAL INSTALL_Range Hood_DG68-01500A.indb 4
MANUAL INSTALL_Range Hood_DG68-01500A.indb 4
2023-01-05 오후 3:15:29
2023-01-05 오후 3:15:29