English 9
Ins
tallation
3.
Check the position for fixing the hood
mounting bracket.
130 mm
Screw Anchors
(2 pcs.)
or 30mm
Screw Anchors
(2 pcs.)
and Washers
(2 pcs.)
4.
Fix the hood mounting bracket
horizontally on the wall where the
hood is to be installed using screw
anchors, hood mounting bracket
screws, and washers.
Be sure to install it on the wall using
the two 30 mm screw anchors.
NOTE
For a secure hold, use a 130 mm screw
anchor.
Connecting the Vent System
NK3*CB600W**
5.
Assemble the damper or the electric
damper for preventing backflow by
turning it in to the hood exhaust
outlet.
NOTE
• Damper is provided in NK3*CB600W**.
• Electric Damper is provided in
NK3*CB700W**.
CAUTION
Check that the electric damper is seated
correctly on the screw thread and there
is no tilt. If the electric damper is not
flush, air will leak through the gap.
NK3*CB700W**
6.
Assemble the damper adapter
pushing into the damper or electric
damper. Fix it using tape.
NOTE
• If the hood is NK3*CB600W**,
please follow it from No.10.
• If the hood is NK3*CB700W**,
please follow it from No.7.
MANUAL INSTALL_Range Hood_DG68-01500A.indb 9
MANUAL INSTALL_Range Hood_DG68-01500A.indb 9
2023-01-05 오후 3:15:31
2023-01-05 오후 3:15:31