10
English
Ins
tallation R
equir
ement
s
Installation Requirements
Installation Clearances
Upper furniture Dimension
30" (Min 77.0 cm)
36" (Max 90.0 cm)
Min 11
7
/
16
"
(29.0 cm)
Required Hood installation Height
Elec : 24" – 36" (61.0 cm – 91.4 cm)
Gas : 27" – 36" (68.5 cm – 91.4 cm)
Min (Vent) 25
7
/
16
" (64.6 cm)
Min (Recirculation) 28
3
/
8
" (72.0 cm)
Making a hole in the furniture
Duct hole guide_Op.1
Cabinet floor drilling work: hood exhaust outlet (damper) cutting work
Rear (Wall)
Front
Duct
Hole
Furniture's Center Line
Min ø 8
5
/
16
"
(21.0 cm)
Min
5
/
16
"
(8.0 cm)
2
15
/
16
" (7.5 cm)
Duct Center Line
CAUTION
•
Cut the cabinet in a way that does not interfere with the damper outlet.
•
After assembling the duct cover, make sure that the cut surface of the cabinet is
not exposed. (The hole size must be smaller than the duct cover.)
•
Vacuum the sawdust to prevent it from blowing away.
•
Make sure the cabinets are not damaged.
•
Before cutting the cabinet, explain to the customer that the cabinet needs to be
cut, and then obtain consent before proceeding.
Method and sequence of cutting the upper cabinets
1.
Refer to the cutting dimensions above and mark the lines to be cut on the cabinet.
2.
Use a jigsaw to cut the upper cabinets. When cutting, use a vacuum cleaner to
minimize the amount of dust.
Installation Tool
Jigsaw
DG68-01416B-02_IB(FULL)_NK30CB700W33AA.indb 10
DG68-01416B-02_IB(FULL)_NK30CB700W33AA.indb 10
2023-05-30 오전 11:18:49