6.3
External Paging
Customer-provided paging equipment can be connected to the PAGING jack using a modular
jack when the NX-DPH/PAGING card is installed (Figure 2-22).
6.4 SMDR / Remote Programming
For Station Message Detailed Recording (SMDR) or remote programming, the NX-SMDR/
R-MMC card should be installed.
The NX-SMDR/R-MMC card provides two (2) serial I/O ports: R-MMC and SMDR. The port
marked 'R-MMC' is used for remote programming and the port marked 'SMDR' is used for
SMDR (Figure 2-23). Port parameters can be set using MMC 80 (see Programming section).
SMDR provides details of outside calls made through the system that can be sent to a
customer-provided printer, data buffers or a CRT. Connect the cable for SMDR as shown
below.
SMDR
(9 PIN)
PRINTER
(25 PIN)
RXD
TXD
SGND
CTS
2
3
5
8
2
3
7
20
TXD
RXD
SGND
DTR
For remote programming, a customer-provided modem should be connected. Connect
the cable for remote programming as shown below.
NX-828
HYBRID KEY SYSTEM
INSTALLATION
Figure 2-22
Connecting External Paging
R-MMC
(9 PIN)
MODEM
(25PIN)
RXD 2
TXD 3
SGND 5
DTR 4
CTS 8
3 RXD
2 TXD
7 SGND
6 DSR
20 DTR
P A G I N G
P AG ING
2 - 20
Summary of Contents for NX-828
Page 1: ......
Page 5: ......
Page 6: ......
Page 15: ...NX SERIES HYBRID KEY SYSTEM GENERAL DESCRIPTION 1 8 ...
Page 16: ......
Page 42: ......
Page 73: ......
Page 80: ...NX 828 HYBRID KEY SYSTEM PROGRAMMING 4 6 ...
Page 161: ......
Page 173: ......
Page 174: ...NX 828 SYSTEM DATABASE FORMS CUSTOMER NAME ADDRESS TELEPHONE NUMBER DATABASE CONTAINS SHEETS ...
Page 186: ......