3. Disassembly and Reassembly
3-2 Removing the Assy-Frame Cooktop
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range. Replace all panels before operating the range. Failure to do
so can result in death or electrical shock.
WARNING
EXPLOSION, FIRE, AND ASPHYXIATION HAZARD
6KXWRIIWKHJDVVXSSO\WRWKHUDQJHEHIRUHVHUYLFLQJ&KHFNDOOJDVOLQHVDQG¿WWLQJVIRUOHDNVEHIRUH
operating the range. Replace all panels before operating the range. Failure to do so can result in death or
SHUVRQDOLQMXU\IURPH[SORVLRQ¿UHRUDVSK\[LDWLRQ
.
CAUTION
When you work on the gas range, be careful when handling sheet metal parts. Sharp edges may be
present, and you can cut yourself if you are not careful.
Parts
([SODQDWLRQ3KRWR
([SODQDWLRQ
Assy-Frame
Cooktop
ASSY GRATE
(2 SIDE / 1 CENTER)
BURNER CAP
BURNER HEAD
BURNER CUP
1.
Turn off the electrical supply
going to the range.
2.
Shut off the gas shut-off valve
in the gas supply line to the
range.
3.
Lift off the three grates.
4.
Lift off the 5 burner caps and
the 5 burner heads from the
burner cups.
5.
Remove screws from the
5 burner cups.
Assy-Frame
Cooktop
SPRING
COOKTOP
CHASSIS
MANIFOLD PANEL
FRAME
COOKTOP
ELECTRODE
6.
Push the 2 spring located
between the frame cooktop and
the chassis manifold panel with a
putty knife.
The knobs should be removed
prior to disassembling the
cooktop frame and make sure
that the Chassis-Manifold Panel
is not damaged during the
operation.
7.
Push the cups down below the
surface of the frame cooktop.
NOTE:
Make sure the electrodes are
below openings in the cooktop to
prevent interference and damage
during removal.