37
3. Disassembly and Reassembly
3-23 Replacing the Assy Valve Safety
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range. Replace all panels before operating the range. Failure to do
so can result in death or electrical shock.
WARNING
EXPLOSION, FIRE, AND ASPHYXIATION HAZARD
6KXWRIIWKHJDVVXSSO\WRWKHUDQJHEHIRUHVHUYLFLQJ&KHFNDOOJDVOLQHVDQG¿WWLQJVIRUOHDNVEHIRUH
operating the range. Replace all panels before operating the range. Failure to do so can result in death or
SHUVRQDOLQMXU\IURPH[SORVLRQ¿UHRUDVSK\[LDWLRQ
CAUTION
When you work on the gas range, be careful when handling sheet metal parts. Sharp edges may be
present, and you can cut yourself if you are not careful.
Parts
([SODQDWLRQ3KRWR
([SODQDWLRQ
Assy Valve
Safety
SUPPORT REGULATOR
[ Rear ]
1.
Turn off the electrical supply going
to the range.
2.
Shut off the gas shut-off valve in
the gas supply line to the range.
3.
Remove the regulator support
bracket from the rear of the range
4.
Carefully identify and mark the
wires going to the ASSY VALVE
SAFETY. Disconnect the 4 wires.
ASSY VALVE SAFETY
[ Front ]
WARNING
Cross-wiring the wires to the
ASSY VALVE SAFETY creates an
H[SORVLRQKD]DUGWKDWFDQUHVXOW
LQGHDWKSHUVRQDOLQMXU\DQGRU
property and product damage.
5.
Using a tubing wrench and a
channel-lock wrench, disconnect
the 3 gas lines from the ASSY
VALVE SAFETY. Do not bend or
crimp gas lines during removal.
6.
Remove
JDV¿WWLQJVIURPWKH
ASSY VALVE SAFETY.
7.
Remove 4 screws and the ASSY
VALVE SAFETY from the back wall
of the warming drawer opening.