4. Troubleshooting
This document can not be used without Samsung’s authorization.
Failure Display Codes
Safety error
“C-21”
Disconnect power and Assy Display PCB
* Check the DLB, Bake and Broil relay. (Normal:∞ Ω)
* Check whether there is any damaged parts of PCB pattern
* Check connector and harness connected to main PCB .
* Check whether harness on connector(CNS303) of
Main PCB is connected normally into the
connector(CNS303) or not .
* Measure thermistor resistance .
(1080Ω at the room temperature)
* Check the connecting condition of
harness related with oven sensor .
*Reconnect after replacing the oven
sensor .
* Replace Main PCB
* Solder again if pattern is damaged
or parts is connected incorrectly .
Ok
No
No
No
Ok
Ok
Ok
There is no problem when you replaced the main PCB .
END
END
END
Replace or repair the
harness .
ConV Relay
Broil Relay
DLB Relay
Bake Relay