86
4. Troubleshooting
This document can not be used without Samsung’s authorization.
Error Trouble Shooting
SYMPTOM
DIAGNOSIS
REMEDY
None of the
cooktop burners
will light .
*
There is no electrical power to the
range .
*
Plug in the power cord and/or reset the
circuit breaker for the range .
*
The gas supply valve to the range is
closed .
*
Open the gas supply valve .
*
Check the terminals on the spark
module for voltage .
*
Replace the faulty spark module .
*
Check for crimped or broken gas line
between the pressure gas regulator
and the surface burner control
manifold .
*
Replace the damaged gas line .
*
Gas pressure regulator switch is
closed .
*
Replace the gas pressure regulator .
One cooktop
burner does not
light .
*
Check the harness connections at the
spark module .
*
Reconnect loose connection or replace
damaged harness .
*
Check the spark module .
*
Disconnect the spark module terminal for
the nonworking burner . If no voltage is
measured, replace the spark module .
*
Check the electrode for that burner .
*
Disconnect the electrode and check whether
electrode wire or tip is broken . Replace the
faulty electrode .
*
Check for a dirty surface burner
orifice.
*
Clean and/or replace the surface burner
orifice.
NOTE:
Replacement orifice should always be
the same size as removed .
*
Check for crimped or broken gas
lines .
*
Replace damaged gas lines .
*
Faulty surface burner control
*
Each surface burner control is an integral
part of the surface burner control manifold .
Replace the manifold .
All surface
burners will light,
but don’t stay lit .
*
Check for crimped gas line between
the pressure gas regulator and the
surface burner control manifold .
*
Replace the damaged gas line .
*
Faulty gas pressure regulator .
*
Replace the gas pressure regulator .
One cooktop
burner lights, but
doesn’t stay lit .
*
Check for a dirty surface burner
orifice.
*
Clean and/or replace the surface burner
orifice.
NOTE:
Replacement orifice should always be
the same size as removed .
*
Check for a crimped gas line .
*
Replace the crimped gas line .
*
Faulty surface burner control .
*
Each surface burner control is an integral
part of the surface burner control manifold .
Replace the manifold .