3. Disassembly and Reassembly
3-5 Removing ASSY PCB DISPLAY
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range . Replace all panels before operating the range . Failure to do so
can result in death or electrical shock .
WARNING
EXPLOSION, FIRE, AND ASPHYXIATION HAZARD
Shut off the gas supply to the range before servicing. Check all gas lines and fittings for leaks before
operating the range . Replace all panels before operating the range . Failure to do so can result in death or
personal injury from explosion, fire, or asphyxiation
.
CAUTION
When you work on the gas range, be careful when handling sheet metal parts . Sharp edges may be present,
and you can cut yourself if you are not careful .
Parts
Explanation Photo
Explanation
ASSY PCB
DISPLAY
ASSY PCB EEPROM
LEVER
1
.
Follow the step A (Remove Cover-
Back Guard Wire)
2
.
Disconnect 4 wire connectors from
the Sub PCB .
3
.
Disconnect a tale of the Membrane
using the lever