81
4. Troubleshooting
Trouble shooting
■ The flame looks abnormal. [Yellow tip / Lift flame]
Yellow tip
/ Lift flame
Check whether the burner heads and
caps are properly assembled .
Check the orifice nozzle diameter.
[NG / LP]
Check the direction of the orifice at
the GPR .
Check the air shutter opening
[Broil / Bake burner]
END
END
END
END
END
No
Ok
Ok
Ok
Ok
No
No
No
Replace the orifice nozzle.
Adjust the air shutter opening
LP
NG
Place the burner heads and caps
properly .
Apply the right direction of the
orifice.
Burner orifice sizes and output rating
(LP Gas [Propane] 10 in WCP)
Burner orifice sizes and output rating
(Natural Gas 5 in WCP)
Burner
Location
BTU Rate
Orifice
Size[mm]
Burner
Location
BTU Rate
Orifice
Size[mm]
RF
12,500
1 .06
RF
16,000
1 .92
LF
11,500
1 .04
LF
15,000
1 .78
RR
4,000
0 .62
RR
5,000
1 .01
LR
7,500
0 .83
LR
9,500
1 .40
CTR
7,500
0 .83
CTR
9,500
1 .40
BAKE
15,000
1 .15
BAKE
18,000
1 .90
BROIL
14,500
1 .12
BROIL
13,500
1 .64