CHAPTER 2.
Ошибка
!
Стиль
не
определен
.
2-134
© SAMSUNG Electronics Co., Ltd.
[420] PRS SIGNAL
Used on a per-trunk basis to define if a Trunk line is to be either a Metering Pulse(MPD) or
a Polarity Reversal Signal(PRS) trunk.
A Meter Pulse Trunk will detect a C.O provided meter pulse. A Polarity Reversal trunk will
detect the line reversal signal which may be provided by the Trunk Line When the other
party answers the outgoing call or the outside party clears the call.
There are three types of PRS mode: PRS 1, PRS 2 and PRS 3.
Type
Description
PRS 1
When first PRS is detected, call duration is started. When second PRS is detected,
call duration timer stopped. The call is not released until hanging-on.
PRS 2
When first PRS is detected, call duration timer is started. When second PRS is
detected, call duration timer is stopped and call is released.
PRS 3
The call duration timer starts based on the timer. When first PRS is detected, call
duration timer is stopped and call is released.
CONDITIONS
y
If the trunk is designated as PRS detection, the call duration timer will be started and
the results printed on the SMDR record.
y
PRS detection is also essential for dropping a trunk-to- trunk conversation which is
unsupervised by an internal party.
DEFAULT DATA
NORMAL(NONE)
ACTION DISPLAY
1) Press Transfer button and enter 420.
Display shows:
[701] TRK PRS
NONE
2) Dial desired trunk number.(e.g., 705)
OR
[705] TRK PRS
NONE
Press Volume button to select trunk and use
Right Soft button to move cursor.
3) Dial 0 for PRS 1, 1 for PRS 2, 2 for PRS 3 or 3
for MPD or 4 for NORMAL.
[705] TRK PRS
PRS 2
OR
Press Volume button to scroll through options and
use Left or Right Soft button to return to step 2.