OfficeServ 500 Programming Guide
© SAMSUNG Electronics Co., Ltd.
2-161
[501] SYSTEM TIMERS
Allows the technician to adjust individual timers as necessary.
TIMER TABLE
Timer Name
Default
Range Unit
Description
AA INT DGT TIME
5
1-25 SEC
When the AA card is installed, this timer
determines the inter digit time for AA call
processing. If this timer expires before valid
digits are received by the AA card, the call will
be routed to the AA invalid digits destination.
AA NO ACT TIME
10
1-25 SEC
When the AA card is installed, this timer
determines the time that the AA card will wait
for a first digit for AA call processing. If this
timer expires before a digit is received, the
call will be routed to the AA no action
destination.
AA TRANS TIME
2
0-25 SEC
After this timer, the system will compare
received digits from AA card with the AA
translation table entry and transfer to the
proper destination.
ALARM TIME
100
0-2500 MIN This is the time the system alarm key will start
ringing after the alarm key has been silenced.
ALERT TONE TIME
1000
100-2500
MSEC
This timer sets the duration of the attention
tone preceding a call to a phone in the Voice
Announce or Auto Answer mode. This tone
will also precede a forced Auto Answer call.
ALM REM.INTERVAL
25
1-250 SEC
This timer controls the time length between
ring attempts at a station when alarm
reminder is set.
ALM REM RING OFF
10
1-25 SEC
This timer controls the length of the ring cycle
duration when alarm reminder is set at a
station.
ATT. RECALL TIME
30
0-250 SEC
This is the length of time a transfer recall will
ring at a station before recalling the operator.
AUTO REDIAL INT.
30
1-250 SEC
This timer controls the time between attempts
after RETRY dialling is set on a station.
AUTO REDIAL RLS.
45
1-250 SEC
This timer controls the duration of a Ring No
Answer condition on a retry number dialed
before the auto redial is automatically cancelled.