OfficeServ 500 Programming Guide
© SAMSUNG Electronics Co., Ltd.
2-173
[504] PULSE MAKE/BREAK RATIO
Allows the ability to change the value of pulses per second and the duration of the
make/break time. This will only affect rotary dial trunks.
No
Item
Description
0
MAKE/BREAK RATIO
Make/Break ratio of dial pulse(01-99)
1
PLUS PER SECOND
Number of dial pulses per second(10 or 20)
CONDITIONS
NONE
DEFAULT DATA
MAKE/BREAK: 33 MAKE
PULSES PER SECOND: 10 PPS
ACTION DISPLAY
1) Press Transfer button and enter 504.
Display shows:
MAKE/BREAK RATIO
33 MAKE
Æ
2) Dial 0 or 1 for option.
OR
PULSE PER SECOND
10 PPS
Æ
_
Press Volume button for selection and press
Right Soft button to move cursor.
3) Dial
new
value.
System returns to step 2.
PULSE PER SECOND
10 PPS
Æ
20
4) Press Transfer button and enter to exit.
OR
Press Speaker button to advance next MMC.
RELATED ITEMS
MMC 402
TRUNK DIAL TYPE