OfficeServ 500 Programming Guide
© SAMSUNG Electronics Co., Ltd.
2-221
[703] TOLL ALLOWANCE TABLE
Provides a way to make toll restriction very easy and flexible. There are 250 allowable
entries in the allow table for a OfficeServ 500-M system and 500 allowable entries for a
OfficeServ 500-L system and each entry index can be assigned to a class of service. Each
index can have up to 12 digits. With the use of wild cards(MMC 704 Assign Wild
Character), more flexibility can be built into toll restriction. There are six toll levels, B to G,
that are programmable. Toll level A is set as unrestricted by default, and toll level H is set
as in-house only by default.
CONDITIONS
NONE
DEFAULT DATA
ALL ENTRIES ARE SET TO 0
PROGRAM BUTTONS
A
Used to wild card X entered
B
Used to wild card Y entered
C
Used to wild card Z entered
ACTION DISPLAY
1) Press
Transfer
button
and
enter
702.
Display shows:
ALOW(001):BCDEFG
:000000
2) Dial index number.(e.g., 005)
OR
ALOW(005):BCDEFG
:000000
Press Volume button to select index and
press Right Soft button to move cursor.
3) Enter toll pattern via dial pad.(e.g., 202)
ALOW(005):BCDEFG
202 :000000
OR
Enter wild card(e.g., 21X) from above list and
press Right Soft button to move cursor to COS
ALOW(005):BCDEFG
20X :000000
Options.