CHAPTER 2.
Ошибка
!
Стиль
не
определен
.
2-312
© SAMSUNG Electronics Co., Ltd.
[759] CLI RINGING
Assigns a specific CID number received from the central office to a specific ring plan
destination. And this programming allows the technician to reject the specific CID number
and assign its own priority. There are 9 priority levels: priority 1 is the highest and priority
9 is the lowest.
It also allows to select the ring tone heard at a phone when called by a specific CID number.
There is also a cadence control option to perform a similar function for single line sets.
There are eight ring tones available along with a Follow Station(NO) option for the phones.
There are 5 cadences and a Follow Station option(NO) for SLT’s
The CID Ringing table consists of 500 entries.
Option
Description
CLI
CID number to be received from the central office. Up to 16 digits may be
entered.
REJ
CID call reject option. When this sets YES, if a call comes that matched CID
number and CLI field then the system will be reject call.
PRI
CID priority option. There are 9 priority levels: priority 1 is the highest and
priority 9 is the lowest. When calls into station group come and group
members are all busy, the system will assign a priority to the CID number so
that calls from a high priority CID number will be placed at the front of the
group queue.
If this option sets NO, the longest call that placed at the group queue has
the highest priority.
R1: XXX, R2: XXX,
R3: XXX, R4: XXX,
R5: XXX, R6: XXX
Ring plan and destination during each ring plan. The destination can be a
station, station group.
Ring Tone options for a specific CID Number.(NO, 1~8)
No
Calls will ring with the phone users choice of ring frequency.
TONE
1~8 Calls from the programmed CID number will ring phones with this
ring frequency.
Ring Cadence options for a specific CID Number at SLT’s(NO, 1~5)
No
Calls will ring with the normal SLT ring cadences.
1
Calls from the programmed CID number will ring SLT’s with the
intercom ring cadence.
2
Calls from the programmed CID number will ring SLT’s with the CO
ring cadence.
3
Calls from the programmed CID number will ring SLT’s with the
DOOR ring cadence.
4
Calls from the programmed CID number will ring SLT’s with the
ALARM ring cadence.
CAD
5
Calls from the programmed CID number will ring SLT’s with the
CALLBACK ring cadence.