[809] LEVEL AND GAIN
Allows the system administrator to set the base level of the TX volume on phones system
wide. There are eight(8) levels those are able to be controlled by the Volume button on
phone. And maximum controllable levels in the system are ten(10). Phone station users can
vary eight levels. So this MMC gives the most flexibility to the system administrator so he
can classify any desired eight(8) levels within eleven(11).
No
Option
Description
Adjusts the transmitting sensitivity(Max.: 9) Default values are
followed:
INDEX: 0 1 2 3 4 5 6 7
0
TX LEVEL CONTROL
LEVEL: 0 1 2 4 3 5 6 7
1
MISC TSW GAIN
Adjusts the level of the internal music source of the MCP card or
the external music source of the MISC card.(0~7, higher numbers
mean lower levels) Default value is 0.
2 TSW
GAIN
CONTROL
Adjusts the tone sensitivity(As shown below, there are 8 types of
matrix connections of the T-Switch that adjusts the tone sensitivity.
Connection between Trunk lines are only applicable when set as 0
in MMC 421.)
0 DGP DLI phone
1 SLT SLI phone
2 ATRK Analog trunk
3 DTRK Digital trunk
4 DECT DECT terminal
5 VOIP MGI port or IP-based phone
6 SVMi SVMi port
7 WLAN WIP port
When changing the MMC [809]
‘MMC [809] LEVEL AND GAIN’ should not be changed from the default levels
without the assistance of the local SAMSUNG distributor.
CONDITIONS
NONE