CHAPTER 2.
Ошибка
!
Стиль
не
определен
.
2-406
© SAMSUNG Electronics Co., Ltd.
(Continued)
No
Code
Alarm Name
Definition
-
MJD--
DTRK Error
ISDN or E1 card Fault
34
MJD01
Sync Failure
Clocking on TEPRI cards has become asynchronous.
35
MJD02
Sync Recovery
Clocking on TEPRI cards has become synchronous.
36
MJD03
Red Alarm
Locally detected loss of PCM carrier on TEPRI card for
more than 250 ms.
Alarm Data = Cabinet, Slot(Cx-Syy)
37
MJD04
Red Alarm Rec
PCM carrier detected locally on TEPRI cards.
Alarm Data = Cabinet, Slot(Cx-Syy)
38
MJD05
Yellow Alarm
Remotely detected failure transmitted in frame on
TEPRI card.
Alarm Data = Cabinet, Slot(Cx-Syy)
39 MJD06 Yellow Alarm
Rec
Remotely detected failure restored transmitted on
TEPRI card.
Alarm Data = Cabinet, Slot(Cx-Syy)
40
MJD07
Blue Alarm
All one's being transmitted on facility on TEPRI card.
Alarm Data = Cabinet, Slot(Cx-Syy)
41
MJD08
Blue Alarm Rec
A blue alarm condition has been cleared.
Alarm Data = Cabinet, Slot(Cx-Syy)
42
MJD09
Bit Error Alarm
Alarm is activated when the when error rate exceeds 1x10
-6
errors. Note: 1x10
-6
is threshold for minor alarm, 1 x 10
-3
is
threshold for major alarm errors on E1,PRI or BRI.
Alarm Data = Cabinet, Slot(Cx-Syy)
43
MJD10
NTWRK Event
An Implausible event has occurred on the PRI or BRI
Network digital line. Protocols do not match or
subscriber ID mismatch.
Alarm Data = Cabinet, Slot Cx-Syy)
44
MJD11
SPID Init Error
The BRI received an error from the network
Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)
45
MJD12
SPID Init Rec
The BRI has recovered from an error on the network
Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)
46
MJD13
LPBK Error
Internal on demand loopback failed.
Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)
47
MJD14
LPBK Recovery
Internal on demand loopback test passed.
Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)
48
MJD15
BRI DL Unavail
A BRI data link is out of service.
Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)
49
MJD16
BRI DL Recovery A BRI data link is back in service.
Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)
50 MJD17 RAM
Error
An
error has occurred in the TEPRI or BRI card RAM.
Alarm Data = Cabinet, Slot(Cx-Syy)