[858] ASSIGN SYSTEM EMERGENCY ALARM
Assigns the alarm for alarm information to send Remote M&A PC via LAN.
Alarm Code Definition
See Alarm Code Definition on MMC 852
CONDITIONS
NONE
DEFAULT DATA
All OFF
ACTION DISPLAY
1) Press Transfer button and enter 858.
Display shows:
01:MJA01 ACT:OFF
POR Restart
2) Enter the alarm entry number.
OR
02:MJA02 ACT:OFF
Soft Restart
Press Volume button to make selection and press
Right Soft button to move cursor.
3) Enter YES or NO(1, 0) for alarming.
OR
02:MJA02 ACT:ON
Soft Restart
Press Volume button to make selection and press
Right Soft button to save and return step 2.
4) Press Transfer button and enter to exit.
OR
Press Speaker button advance to next MMC.
RELATED ITEMS
MMC 852
ALARM KEY ASSIGNMENTS