CHAPTER 2. MMC Programming
2-170
© SAMSUNG Electronics Co., Ltd.
(Continued)
Timer Name
Default
Range Unit
Description
KMMC LOCK OUT TM
30
10-50 SEC
This timer controls the grace period between
programming actions while in a programming
session. The timer automatically returns the
system to secure programming status.
LCR ADVANCE TIME
5
1-250 SEC
This timer controls the time before selecting
the next allowable route when a station is
allowed to route advance.
LCR INTER DIGIT
5
1-250 SEC
This timer controls the grace period between
dialing valid digits before accessing a trunk.
LONG KEY DETECT
600
0-2500
MSEC
This timer controls the time a key must be held
down before the key press is repeated.
LONG KEY REPEAT
300
0-2500
MSEC
This timer controls the time between repeated
digits on a long key press.
MCL DELAY TIME
4
0-9 SEC
This timer controls the time when the system
should start transmitting Authorisation Code
after sending MCL access code (Cable&
Wireless 131 access). Available in UK only.
MS LED ON TIME
5
1-10 SEC
This timer controls the duration a Manual
Signaling key will remain on after use.
OFF HOOK RING INT
15
1-250 SEC
This timer controls the time between ring
bursts to a user who has a camped-on call.
OHVA ANSWER TIME
10
1-250 SEC
This timer controls the time allowed to answer
an OHVA call before automatic rejection.
PAGE TIME OUT
20
1-250 SEC
This timer controls the duration of a page
announcement.
PAGE TONE TIME
500
100-2500
MSEC
This timer controls the duration of tone burst
heard over the page prior to the page
announcement.
PARK RECALL TIME
45
0-250 SEC
This timer controls how long a call is parked
before recalling to the call park originator.
AP-MMC LOCK TIME
5
1-60 MIN
This timer monitors the PCMMC/WebMMC/
Installer activity, drops the link if no action is
created by PCMMC and returns the system
back to secure program status.
PERI UCD REPORT
5
3-99 SEC
This timer determines the interval between
periodic UCD reports provided to an SIO port.
POWER DOWN TIME
2000
500-9900
MSEC
This timer monitors the power to the ROM
pack to begin shutdown status.
RECALL
DISCONNECT
2
1-250 MIN
This is the time an attendant recall will ring
before being disconnected.
Summary of Contents for OfficeServ 7000 Series
Page 1: ...GABD 000264 Ed 02 OfficeServ 7000 Series Call Server Programming Manual ...
Page 6: ...Revision History IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 18: ...TABLE OF CONTENTS XVI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 82: ...CHAPTER 2 MMC Programming 2 44 SAMSUNG Electronics Co Ltd RELATED ITEMS NONE ...
Page 486: ...ABBREVIATION VI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...