OfficeServ 7000 Series Call Server Programming Manual
© SAMSUNG Electronics Co., Ltd.
2-171
(Continued)
Timer Name
Default
Range Unit
Description
RECALL WAIT TIME
15
0-250 SEC
This is the time any recall (hold or transfer)
continues to recall at your station before it
recalls to the operator.
ROUTE OPTIMISE
5
0-250 SEC
When a call is made via Q-SIG Signaling,
route optimization is activated after this time.
SMDR START /DP
30
1-250 SEC
This grace period timer starts SMDR
recording for rotary dialing.
SMDR START /DTMF
15
1-250 SEC
This grace period timer starts SMDR recording
for touchtone dialing. This timer also controls
the LCD duration timer on the phones. The
duration time displayed and the SMDR time
duration will be the same.
SYS HOLD RECALL
45
0-250 SEC
This timer determines the time calls can be
left on hold before recalling to the holding
station. This is a system-wide timer. Setting
the timer to 000 means that no recalling will
take place.
TRANSFER RECALL
20
0-250 SEC
This timer determines how long transferred
calls ring before recalling. This is a system-
wide timer.
TRK AUTOMOH DISC
60
1-250 SEC
When set to ON, incoming trunk calls are
connected to MOH automatically after the
DISA ANSWR timer (MMC 503) expires.
In this case the caller hears MOH. If the TRK
AUTOMOH DISC timer expires before the
call is answered, the call is disconnected.
TSW CONN. DELAY
0
0-10
SEC
When an incoming trunk makes an outgoing
call to another trunk, the system connects the
voice path after this time.
UCDS AUDIO ALARM
0
0-990 SEC
When an SVMi-20 card is installed and the digital
UCD package enabled, this counter determines
the maximum number of seconds a call has
been waiting at the UCD group before the UCD
group’s SUPV key begins to flash along with an
audio alarm. For more UCD alarm conditions,
see MMC 500.
UCDS VISUAL ALARM
0
0-250 SEC
When an SVMi-20 card is installed and the
digital UCD package enabled, this counter
determines the maximum number of seconds
a call at the UCD group before the UCD
group’s SUPV key begins to flash as an
alarm. For more UCD alarm conditions, see
MMC 500.
Summary of Contents for OfficeServ 7000 Series
Page 1: ...GABD 000264 Ed 02 OfficeServ 7000 Series Call Server Programming Manual ...
Page 6: ...Revision History IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 18: ...TABLE OF CONTENTS XVI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 82: ...CHAPTER 2 MMC Programming 2 44 SAMSUNG Electronics Co Ltd RELATED ITEMS NONE ...
Page 486: ...ABBREVIATION VI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...