CHAPTER 2. MMC Programming
2-172
© SAMSUNG Electronics Co., Ltd.
(Continued)
Timer Name
Default
Range Unit
Description
VM RBK DELAY TM
0
0-250 SEC
In case of an incoming call, the answer time
for VM ringback tone is delayed
VOIP RE-ROUTE TM
15
0-25 SEC
If an outgoing call made via a VoIP trunk
does not receive an acknowledgement
message from the called party within this
time, the call is treated as failed.
When timers value is ‘0’
Some timers are disabled when their value is set to ‘0’.
DEFAULT DATA
SEE DESCRIPTION
SOME TIMERS DEPEND ON COUNTRY
ACTION
DISPLAY
1) Press Transfer button and enter 501.
Display shows first timer value:
AA INT DGT TIME
05 SEC
2) Press Volume button to select timer and press Right
Soft button to move cursor.
KMMC LOCK OUT TM
060 SEC
3) Enter new value using keypad; if valid, system
returns to step 2 with new value.
KMMC LOCK OUT TM
060 SEC
250
4) Press Transfer button to save and exit.
OR
Press Speaker button to advance to next MMC.
RELATED ITEMS
NONE
Summary of Contents for OfficeServ 7000 Series
Page 1: ...GABD 000264 Ed 02 OfficeServ 7000 Series Call Server Programming Manual ...
Page 6: ...Revision History IV SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 18: ...TABLE OF CONTENTS XVI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...
Page 82: ...CHAPTER 2 MMC Programming 2 44 SAMSUNG Electronics Co Ltd RELATED ITEMS NONE ...
Page 486: ...ABBREVIATION VI SAMSUNG Electronics Co Ltd This page is intentionally left blank ...